@@ -2,16 +2,17 @@
|
|
|
|
|
|
The action is used for publish output message into a MQTT server.
|
|
|
|
|
|
-| Property name | Optional | Description |
|
|
|
-| ------------------ | -------- | ------------------------------------------------------------ |
|
|
|
-| server | false | The broker address of the mqtt server, such as ``tcp://127.0.0.1:1883`` |
|
|
|
-| topic | false | The mqtt topic, such as ``analysis/result`` |
|
|
|
-| clientId | true | The client id for mqtt connection. If not specified, an uuid will be used |
|
|
|
-| protocol_version | true | 3.1 (also refer as MQTT 3) or 3.1.1 (also refer as MQTT 4). If not specified, the default value is 3.1. |
|
|
|
-| username | true | The user name for the connection. |
|
|
|
-| password | true | The password for the connection. |
|
|
|
-| certification_path | true | The certification path. It can be an absolute path, or a relative path. If it is an relative path, then the base path is where you excuting the ``server`` command. For example, if you run ``cli/server`` from ``/var/kuiper``, then the base path is ``/var/kuiper``; If you run ``./server`` from ``/var/kuiper/bin``, then the base path is ````/var/kuiper/bin``. |
|
|
|
-| private_key_path | true | The private key path. It can be either absolute path, or relative path. For more detailed information, please refer to ``certification_path``. |
|
|
|
+| Property name | Optional | Description |
|
|
|
+| ----------------- | -------- | ------------------------------------------------------------ |
|
|
|
+| server | false | The broker address of the mqtt server, such as ``tcp://127.0.0.1:1883`` |
|
|
|
+| topic | false | The mqtt topic, such as ``analysis/result`` |
|
|
|
+| clientId | true | The client id for mqtt connection. If not specified, an uuid will be used |
|
|
|
+| protocolVersion | true | 3.1 (also refer as MQTT 3) or 3.1.1 (also refer as MQTT 4). If not specified, the default value is 3.1. |
|
|
|
+| qos | true | The QoS for message delivery. |
|
|
|
+| username | true | The user name for the connection. |
|
|
|
+| password | true | The password for the connection. |
|
|
|
+| certificationPath | true | The certification path. It can be an absolute path, or a relative path. If it is an relative path, then the base path is where you excuting the ``server`` command. For example, if you run ``bin/server`` from ``/var/kuiper``, then the base path is ``/var/kuiper``; If you run ``./server`` from ``/var/kuiper/bin``, then the base path is ``/var/kuiper/bin``. |
|
|
|
+| privateKeyPath | true | The private key path. It can be either absolute path, or relative path. For more detailed information, please refer to ``certificationPath``. |
|
|
|
|
|
|
Below is sample configuration for connecting to Azure IoT Hub by using SAS authentication.
|
|
|
```json
|
|
@@ -19,7 +20,7 @@ Below is sample configuration for connecting to Azure IoT Hub by using SAS authe
|
|
|
"mqtt": {
|
|
|
"server": "ssl://xyz.azure-devices.net:8883",
|
|
|
"topic": "devices/demo_001/messages/events/",
|
|
|
- "protocol_version": "3.1.1",
|
|
|
+ "protocolVersion": "3.1.1",
|
|
|
"qos": 1,
|
|
|
"clientId": "demo_001",
|
|
|
"username": "xyz.azure-devices.net/demo_001/?api-version=2018-06-30",
|
|
@@ -37,8 +38,8 @@ Below is another sample configuration for connecting to AWS IoT by using certifi
|
|
|
"topic": "devices/result",
|
|
|
"qos": 1,
|
|
|
"clientId": "demo_001",
|
|
|
- "certification_path": "keys/d3807d9fa5-certificate.pem",
|
|
|
- "private_key_path": "keys/d3807d9fa5-private.pem.key"
|
|
|
+ "certificationPath": "keys/d3807d9fa5-certificate.pem",
|
|
|
+ "privateKeyPath": "keys/d3807d9fa5-private.pem.key"
|
|
|
}
|
|
|
}
|
|
|
```
|