@@ -11,6 +11,24 @@ The action is used for publish output message into EdgeX message bus.
|
|
|
| contentType | true | The content type of message to be published. If not specified, then use the default value ``application/json``. |
|
|
|
| metadata | true | The property is a field name that allows user to specify a field name of SQL select clause, the field name should use ``meta(*) AS xxx`` to select all of EdgeX metadata from message. |
|
|
|
| deviceName | true | Allows user to specify the device name in the event structure that are sent from Kuiper. |
|
|
|
+| type | true | The message bus type, two types of message buses are supported, ``zero`` or ``mqtt``, and ``zero`` is the default value. |
|
|
|
+| optional | true | If ``mqtt`` message bus type is specified, then some optional values can be specified. Please refer to below for supported optional supported configurations. |
|
|
|
+
|
|
|
+Please notice that all of values in optional are **<u>string type</u>**, so values for these configurations should be string - such as ``KeepAlive: "5000"``. Below optional configurations are supported, please check MQTT specification for the detailed information.
|
|
|
+
|
|
|
+- optional
|
|
|
+ - ClientId
|
|
|
+ - Username
|
|
|
+ - Password
|
|
|
+ - Qos
|
|
|
+ - KeepAlive
|
|
|
+ - Retained
|
|
|
+ - ConnectionPayload
|
|
|
+ - CertFile
|
|
|
+ - KeyFile
|
|
|
+ - CertPEMBlock
|
|
|
+ - KeyPEMBlock
|
|
|
+ - SkipCertVerify
|
|
|
|
|
|
## Examples
|
|
|
|
|
@@ -120,4 +138,35 @@ Please notice that,
|
|
|
- For the reading that can NOT be found in original message, the metadata will not be set. Such as metadata of ``t1`` in the sample will fill with default value that generated by Kuiper.
|
|
|
- If your SQL has aggregated function, then it does not make sense to keep these metadata, but Kuiper will still fill with metadata from a particular message in the time window. For example, with following SQL,
|
|
|
```SELECT avg(temperature) AS temperature, meta(*) AS edgex_meta FROM ... GROUP BY TUMBLINGWINDOW(ss, 10)```.
|
|
|
-In this case, there are possibly several messages in the window, the metadata value for ``temperature`` will be filled with value from 1st message that received from bus.
|
|
|
+In this case, there are possibly several messages in the window, the metadata value for ``temperature`` will be filled with value from 1st message that received from bus.
|
|
|
+
|
|
|
+## Send result to MQTT message bus
|
|
|
+
|
|
|
+Below is a rule that send analysis result to MQTT message bus, please notice how to specify ``ClientId`` in ``optional`` configuration.
|
|
|
+
|
|
|
+```json
|
|
|
+{
|
|
|
+ "id": "rule1",
|
|
|
+ "sql": "SELECT meta(*) AS edgex_meta, temperature, humidity, humidity*2 as h1 FROM demo WHERE temperature = 20",
|
|
|
+ "actions": [
|
|
|
+ {
|
|
|
+ "edgex": {
|
|
|
+ "protocol": "tcp",
|
|
|
+ "host": "127.0.0.1",
|
|
|
+ "port": 1883,
|
|
|
+ "topic": "result",
|
|
|
+ "type": "mqtt",
|
|
|
+ "metadata": "edgex_meta",
|
|
|
+ "contentType": "application/json",
|
|
|
+ "optional": {
|
|
|
+ "ClientId": "edgex_message_bus_001"
|
|
|
+ }
|
|
|
+ }
|
|
|
+ },
|
|
|
+ {
|
|
|
+ "log":{}
|
|
|
+ }
|
|
|
+ ]
|
|
|
+}
|
|
|
+```
|
|
|
+
|